using System; using System.Runtime.InteropServices; using System.Threading; using RynthCore.Engine.Hooking; namespace RynthCore.Engine.Compatibility; internal static class LoginLifecycleHooks { private const int ExpectedImageSize = 0x56D000; private static readonly byte?[] SendLoginCompletePattern = [ 0x6A, 0x01, 0xC6, 0x86, null, null, null, null, 0x01, 0xE8, null, null, null, null, 0x8B, 0x0D, null, null, null, null, 0x83, 0xC4, 0x04, 0x6A, 0x00, 0x6A, 0x0B, 0xE8 ]; private static readonly byte[] SendLoginCompletePrologue = [0x56, 0x8B, 0xF1]; [UnmanagedFunctionPointer(CallingConvention.ThisCall)] private delegate void SendLoginCompleteNotificationDelegate(IntPtr thisPtr); private static SendLoginCompleteNotificationDelegate? _originalSendLoginCompleteNotification; private static SendLoginCompleteNotificationDelegate? _sendLoginCompleteNotificationDetour; private static IntPtr _targetAddress; private static string _statusMessage = "Not probed yet."; private static long _nextStatusLogTick; private static bool _waitingLogged; public static bool IsInstalled { get; private set; } public static bool HasObservedLoginComplete { get; private set; } /// When login completed (TickCount64), or 0 before it / after a logout. A hot reload /// marks it at the reload. AutoId defers its background appraisals 30 s past it. public static long LoginCompleteAtMs => System.Threading.Interlocked.Read(ref _loginCompleteAtMs); private static long _loginCompleteAtMs; public static string StatusMessage => _statusMessage; public static event Action? LoginComplete; public static void Initialize() { if (IsInstalled) return; if (!AcClientModule.TryReadTextSection(out AcClientTextSection textSection)) { _statusMessage = "acclient.exe not available."; return; } try { int imageSize = textSection.ImageSize; if (imageSize != ExpectedImageSize) RynthLog.Verbose($"Compat: login lifecycle hook using unverified acclient image size 0x{imageSize:X} (expected 0x{ExpectedImageSize:X})."); int callSiteOff = PatternScanner.FindPattern(textSection.Bytes, SendLoginCompletePattern); if (callSiteOff < 0) { _statusMessage = "SendLoginCompleteNotification call site pattern not found."; RynthLog.Compat($"Compat: login lifecycle hook failed - {_statusMessage}"); return; } int funcOff = PatternScanner.FindPrologueBefore( textSection.Bytes, callSiteOff, SendLoginCompletePrologue, maxDistance: 0x100); if (funcOff < 0) { _statusMessage = "SendLoginCompleteNotification prologue not found."; RynthLog.Compat($"Compat: login lifecycle hook failed - {_statusMessage}"); return; } _targetAddress = new IntPtr(textSection.TextBaseVa + funcOff); _sendLoginCompleteNotificationDetour = SendLoginCompleteNotificationDetour; IntPtr detourPtr = Marshal.GetFunctionPointerForDelegate(_sendLoginCompleteNotificationDetour); _originalSendLoginCompleteNotification = Marshal.GetDelegateForFunctionPointer(MinHook.HookCreate(_targetAddress, detourPtr)); Thread.MemoryBarrier(); MinHook.Enable(_targetAddress); IsInstalled = true; _statusMessage = $"Hooked SendLoginCompleteNotification @ 0x{_targetAddress.ToInt32():X8}."; _nextStatusLogTick = Environment.TickCount64 + 3000; RynthLog.Info( $"LoginLifecycleHooks: target=0x{_targetAddress.ToInt32():X8} (funcOff=0x{funcOff:X8}, callSite=0x{textSection.TextBaseVa + callSiteOff:X8}, prologueDistance={(textSection.TextBaseVa + callSiteOff) - _targetAddress.ToInt32()} bytes)."); } catch (Exception ex) { _statusMessage = ex.Message; RynthLog.Compat($"Compat: login lifecycle hook failed - {ex.Message}"); } } /// /// Clears the one-shot observation flag so the next SendLoginCompleteNotification /// raises again. Called by the logout pipeline so the /// following login (e.g. swapping characters) re-runs login-gated startup. /// public static void ResetObservation() { HasObservedLoginComplete = false; System.Threading.Interlocked.Exchange(ref _loginCompleteAtMs, 0); // Queued engine work (appraisals, health queries, chat, actions) from this login is stale // for the next one (2026-10-06, AcMainThreadQueue). try { AcMainThreadQueue.NewLoginEpoch(); } catch { } _statusMessage = "Awaiting next SendLoginCompleteNotification."; _waitingLogged = false; } public static void Poll() { if (HasObservedLoginComplete || !IsInstalled) return; long now = Environment.TickCount64; if (now < _nextStatusLogTick) return; _nextStatusLogTick = now + 3000; if (!_waitingLogged) { _waitingLogged = true; RynthLog.Verbose("Compat: login lifecycle awaiting SendLoginCompleteNotification."); } } private static void SendLoginCompleteNotificationDetour(IntPtr thisPtr) { RecursionGuard.Tick("LoginLifecycleHooks.SendLoginCompleteNotification"); _originalSendLoginCompleteNotification!(thisPtr); SignalLoginComplete("CPlayerSystem::SendLoginCompleteNotification"); } private static void SignalLoginComplete(string source) { if (HasObservedLoginComplete) return; HasObservedLoginComplete = true; System.Threading.Interlocked.Exchange(ref _loginCompleteAtMs, Environment.TickCount64); _statusMessage = $"Login complete observed via {source}."; RynthLog.Verbose($"Compat: login complete observed via {source}."); LoginComplete?.Invoke(); } /// /// Mark login as already complete and fire the /// event without waiting for the AC client's /// SendLoginCompleteNotification. Used by the hot-reload path: the /// new engine instance starts after the game is already in-world, so the /// notification will never fire again — we synthesize it so subscribers /// (PluginManager, D3D9 bootstrapper) reach their post-login state. /// public static void MarkAlreadyComplete(string source) { SignalLoginComplete(source); } }